- Prior Vermason Item Number: H670
- Uses a reliable current loop principle (not capacitance method)
- Test voltage is 5VDC max, test current is 5:Amax
- Visual and audible alarms
- Wrist strap test calibrated to indicate fail low 0.75 megohms and fail high 35 megohms
|
|