• Single Station Continuous Monitors for Operator And ESD Work Surface
Continuously moniitors the integrity of one operator and ESD workstation,
eliminating the need for periodic testing and recording. Ideal for individual
assembly, test, packaging, workstation, or other applications.
• Wave Distortion Technology Provides Real-Time Continuous Monitoring
of Operator Path to Ground and Presence of 1 Meg Resistor
True continuous monitoring (versus pulsed or intermittent) of wrist strap
functionality and operator safety according to accepted industry standards.
• Work Surface Monitoring May Be Disabled (NEW)
Flexibility for work areas where an ESD work surface is not used such as the
operator of an SMT machine or oven.
• Full Time Dual Status LEDs (NEW) and Audible Alarm for Operator and
Workstation Monitoring.
Audible and LED visual alarms activate instantly when a failure occurs, alerting
user and supervisor of problem, allowing immediate corrective action
• Easy to Install Housing with Screws or Adhesive Backed Velcro® Strips
Optional mounting suitable to most machinery and work area, even in hard to
reach locations
• Calibration Unit Available for Accurate Performance And Conformity
Testing In The Field (See Vermason Item 222750 Click Here)
• NIST Calibrated with Certificate
Calibrated with accepted procedures and standards traceable to the National
Institute of Standards and Technology. For more information on calibration of
Vermason products, see Calibration
• Made in America |
 |
|
 |
 |
 |
 |
 |
 |
 |
 |
| Item |
Description |
Price |
| 222605 |
Continuous Multi-Mount Monitor, 220V |
£88.31 |
|
 |
 |
 |
 |
 |
 |
 |
Wrist strap testing “Where continuous monitoring is used, no additional testing is required.” [EN 61340-4-1, per A.5.2]
“The main advantage to a constant monitor is the immediate indication that the employee receives if the wrist strap falls open. With an unmonitored system, the employee will not be aware of a wrist strap failure until the start of the next shift. This has reliability benefits for an ESD program as it might help reduce or eliminate ESD damage.
There are also other process benefits from using constant monitors such as the elimination of the need to maintain daily test logs and a reduction in the time for employees to make the daily test. For units that also monitor the connection of a work surface to protective earth, it is also possible to reduce or eliminate the checking of the work surface as part of the periodic audit of the process.” [CLC/TR 61340-5-2:2008 User guide Annex B.1.3 Constant monitors] |
 |
 |
 |
 |
|
 |
 |
|
 |
 |
 |
If you would rather not receive these emails: please Click Here |
 |
 |
If you are having trouble with the unsubscribe feature, e-mail Ian.Isation@StaticExperts.com |
 |
 |
 |
 |
 |
| Vermason.co.uk |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|